LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry

LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry
LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry

Large Image :  LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry

Product Details:
Place of Origin: Shenzhen, China
Brand Name: LABNOVATION
Certification: IFCC, NGSP, CE
Model Number: LD-100
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Carton
Delivery Time: 10 work day
Payment Terms: D/A, D/P, T/T
Supply Ability: 100/Day

LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry

Description
Size: 220mm*150mm*120mm Weight: 800g
Shelf Life: 9 Months Analytical Wave-length: 510nm And 580nm
Sample Volume: 4μl Full-blood Input Power: <60VA
High Light:

LD100 automatic hematology analyzer

,

LD100 POCT automatic hematology analyzer

,

LD100 510nm automatic hematology analyzer

HbA1c Analyzer LD-100 Hemoglobin Testing Analyzer POCT One Step Detection Fast Testing Analyzer

Intended Use

  • It is intended for the determination of percent hemoglobin A1c (HbA1c) in human whole blood.
  • It is a semi-automatic instrument used to analyze glycated hemoglobin.
  • It can be used to detect of HbA1c in medical units at all levels.And it's very protable to carry, you can testing HbA1c anytime.
  • It has fully automatic system just need one step operation then the test will be start.

Specifications

Model LD-100
Sample Type Whole blood
Sample Volume 4ul
Test Time Less than 3 minutes
Data storage 7000
Method Fluorescent Immunoturbidimetry
Operating Type 1-Step Operation, Fully automatic system
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Voltage 12VDC-3.33A
Analytical wave-length 510nm and 580nm.
Certification NGSP, IFCC

 

LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry 0

 

PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • Easy to operate, One Step Testing
  • High Accuracy
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • Color touch screen
  • External printer (Blue-tooth)
  • USB Port, LIS Support
  • One analyzer for testing without extra instrument

 

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

LD100 510nm 580nm Automatic Hematology Analyzer Fluorescent Immunoturbidimetry 1

 

Performance Parameters

  • Accuracy: Is tested with the reference material as samples and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.

 