Home ProductsNeutralizing Antibody Test Kit

ISO13485 Rapid Neutralizing Antibody Test Kit 95.00% Acuracy

Certification
China Labnovation Technologies, Inc. certification
China Labnovation Technologies, Inc. certification
I'm Online Chat Now

ISO13485 Rapid Neutralizing Antibody Test Kit 95.00% Acuracy

ISO13485 Rapid Neutralizing Antibody Test Kit 95.00% Acuracy
ISO13485 Rapid Neutralizing Antibody Test Kit 95.00% Acuracy ISO13485 Rapid Neutralizing Antibody Test Kit 95.00% Acuracy

Large Image :  ISO13485 Rapid Neutralizing Antibody Test Kit 95.00% Acuracy

Product Details:
Place of Origin: China
Brand Name: LABNOVATION
Certification: ISO13485,ISO9001,CE
Model Number: LX-401701
Payment & Shipping Terms:
Minimum Order Quantity: 10000/Pieces
Price: US $0.7-1/Piece
Packaging Details: Carton
Delivery Time: 5-7 work day
Payment Terms: D/A, D/P, T/T
Supply Ability: 500000/Day

ISO13485 Rapid Neutralizing Antibody Test Kit 95.00% Acuracy

Description
Specimen: Serum, Plasma, Whole Blood Group: All People
Certification: ISO13485, ISO9001, CE Test Speed: Within 15 Minutes
Storage: 2℃-30℃ Humidity: 35%-60%
High Light:

ISO13485 Neutralizing Antibody Test Kit

,

Rapid Neutralizing Antibody Test Kit

,

rapid antibody test kit 95.00% Acuracy

Rapid Test Kit Neutralizing Antibody Rapid Test Kit High Quality Detection Rapid Antibody Test Kit

 

Intended Use

  • The Labnovation's SARS-CoV-2 neutralizing antibody rapid test kit is intended for the semi-quantitative determination of neutralizing antibodies to SARS-CoV-2 in human serum, plasma, fingersitick whole blood or venous whole blood specimens.
  • The test is intended use as an aid in identifying individuals with an adaptive immune response to SARS-COV-2, indicating recent or prior infection or assisting in evaluating the effectiveness of the vaccine clinical trials and mass vaccination.
  • Results are for the detection of total neutralizing antibodies to SARS-COV-2. Antibodies to SARS-COV-2 are generally detectable in blood several days after initial infection.

Specifications

Test Item Neutralizing Antibody Test Kit
Number LX-401701
Specificity 98.00%
Sensitivity 97.67%
Total Acuracy > 95.00%
Humidity 35%-60%
Storage Temperature 2-30°C
Sample Type Whole bloo, Serum, Plasma
Sample Volume Whole blood 20µL, Serum/Plasma 10µL
Package 20 Tests/Kit
nspection Method Immunochromatography
Shelf Life 18 Months
Type IVD Antibody Rapid Test
Application For Professional Testing Use

ISO13485 Rapid Neutralizing Antibody Test Kit 95.00% Acuracy 0

Main Components

  • 20 Test cassettes
  • 20 Disposable pipettes
  • 20 Sterile Safety Lancets
  • 1 Sample Buffer
  • 1 Colorimetric chart
  • 1 Instruction for use

Product Feature

  • Fast Test, get antigen test result within 10-15 minutes.
  • High sensitivity and specificity
  • Easy to operate, no need equipment, convenient and fast
  • Require little Specimens

ISO13485 Rapid Neutralizing Antibody Test Kit 95.00% Acuracy 1

Advantage

  • It can not only screen in the window period of infection oneset but also indicate the previous infection and reduce the rate of missed diagnosis
  • Blood sample detection , simple samplig, simple operation
  • Combined with nucleic acid kit to improve the screening rate of suspected patients
  • Rapid screening within 10-15minutes, resukts effective for 15minutes
  • Single detection, visual interpretation, no equipment, to adapt to the community
  • Easy operation, compatible with different samples
  • Room temperature storage

 

Notic

  • Sample should be human serum, plasma and whole blood only, other body fluid samples are not tested and may cause incorrect or inaccurate results.
  • All reagents have to be brought to room temperature (18 to 25 °C) before performing the test.

Use Step

  • Place the lanceton the test site.
  • Push down the lancet.
  • Collect the bloodby transfer pipette.

ISO13485 Rapid Neutralizing Antibody Test Kit 95.00% Acuracy 2

  • Add one drop of blood into the sample well.
  • Add 1-2 drops (30-60µL) of sample buffer into the sample well innediately.
  • Wait 15 minutes then read the result.

ISO13485 Rapid Neutralizing Antibody Test Kit 95.00% Acuracy 3

 

Interpretation of results

  • POSITIVE: The T line and C line are both displayed within the reaction window, indicates the neutralizing antibodies to SARS-COV-2 are detected. The result is positive.
  • NEGATIVE:The C line is displayed within the reaction window only, indicates absence of neutralizing antibody to SARS-COV-2.The result is negative..
  • INVALID:1. If the control (C) line is not displayed in 15 min, regardless of whether T line is present, the test result is invalid. It is recommended that the specimen should be re-tested.
    The test result is invalid after 20 min.

ISO13485 Rapid Neutralizing Antibody Test Kit 95.00% Acuracy 4

LIMITATIONS

  • The test is for in vitro diagnostic use only.
  • This test is designed for semi-quantitative detection of SARS-COV-2 neutralizing antibodies.
  • It is unknown at this time if the presence of antibodies to SARS-COV-2 confers immunity to re-infection. Consider other information including clinical history and local disease prevalence, in assessing the need for a second but different serology test to confirm an immune response.
  • The test results of this kit are for clinical reference only, and should not be used as the sole basis, and should be combined with other test methods, as live virus and pseudovirus neutralizing antibodies assay.

Application

  • Hospitals
  • Enterprise
  • School
  • Community
  • Family

FAQ

 

  • MOQ:

We have the MOQ limit,which is 10000 pieces.

  • Delivery date:

After order confirmed,we will arrange your order immediately,and offer you an
estimated delivery date.

  • Payment Method:

Business to business account.

  • Shipment:

We choose Air cargo or Ocean cargo.

  • Trade Company or Manufacturer:

Manufacturer

Contact Details
Labnovation Technologies, Inc.

Contact Person: Ld

Tel: +8613480985156

Send your inquiry directly to us (0 / 3000)