Product Details:
|
Principle: | HPLC (High Performance Liquid Chromatography) | Test Speed: | 90s/test |
---|---|---|---|
Sample Types: | Whole Blood Or Pre-diluent Sample | Test Blood Volume: | 5μL In Whole Blood Mode; 150μL In Pre-diluted Mode |
Sample Loading Method: | Continuous Automatic Sample Loading | Sample Capacity: | 20 Samples |
Reagent Pack: | 600T | Column Test Quantity: | 3000T |
Eluent Kind: | Eluent A, Eluent B | Data Storage: | 5000 |
Built-in Thermal Printer: | Yes | CV: | <2% |
Test Range: | 3.0%~18.0% | Operation Screen: | 10" Full Color LCD Display |
Gross Weiht: | 28kg | Dimensions: | 378(L) ×380(W)×510(H)mm |
Shelf Life: | 5 Years |
Fully Automated HbA1c Analyzer HPLC Method Best Performance CV<2% Stable And Efficient
Intended use
Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidic cation exchanger.
Glycosylation of hemoglobin results in a loss of surface cations that are uncharged, and non-glycosylated hemoglobin is positively charged.
According to the different charged properties of hemoglobin, several hemoglobin components including HbA1c were separated by high performance liquid chromatography using cleaning solutions of different pH values and ionic strengths.
Each component is detected by a single wavelength colorimeter, and the data is processed by a microcomputer to calculate the percentage content of HbA1c in the total hemoglobin.
*HPLC Technology
Anchored to the Diabetes Control and Complication Trial (DCCT) reference study NGSP and IFCC certified
*Fast
HbAlc results in 90 seconds
*Fully Automated
Automated Piercing
Fully Automated Start-up, Maintenance and Shutdown Internal Auto Barcode Scanner for Sample identification
*Precise and Reliable
HbAlc Inter & Intra Measuring CV<2% to Enable Exceptional Result Management Superior Quality Chromatographic Resolution to Minimize Interferences
Specification
Instrument | Manufacturer | Lanovation |
Manufacture location | Shenzhen, China | |
Model | LD-560 | |
Dection information | Principle method | HPLC |
Detection method | Dual wavelengh colorimetry | |
Wavelength | 420nm | |
Test Speed | 90 Seconds/test | |
Test Speed throughtput | 40 Samples per hour | |
Sample information | Sample types | Whole blood or Pre-diluent sample |
Sample volume | 5μL in whole blood mode 150μL in pre-diluted mode |
|
Sample capacity | 20 samples | |
Sample loading method | Continuous automatic sample loading | |
Mixer | No, but probe mixing samples | |
Reagent and other consumble | Column test quantity | 3000T |
Reagent pack | 600T(Reagent)/ 3000T(Column) separate | |
Eluent | 2 | |
Operation and character information | Operation screen | 10 inch Full color LCD display |
Data storage | 5000 | |
Built-in Thermal Printer | Yes | |
Performance information | CV | <2% |
Test range | 3.0%~18.0% | |
Package Information |
Dimensions | 378(L) ×380(W)×510(H)mm |
Weight | 28kg |
Reagents and Consumables
Eluent A/Eluent B/Eluent C(Variant Mode) | Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin. |
Hemolysis Reagent | Used to dissolve red blood cells and release hemoglobin. |
Chromatography Column | Used for separation and elution of glycosylated hemoglobin and non glycated. |
Hemoglobin Filter | Used to initially filter the sample after hemolysis. |
Paper Rolls | Prints a report of the test results. |
Advantage
Certificate
Contact Person: Miss. Aimee li
Fax: 86-755-86368318