98.02% Accuracy Universal RTK Antigen Test Kit Double Antibody Sandwich Method

98.02% Accuracy Universal RTK Antigen Test Kit Double Antibody Sandwich Method
98.02% Accuracy Universal RTK Antigen Test Kit Double Antibody Sandwich Method 98.02% Accuracy Universal RTK Antigen Test Kit Double Antibody Sandwich Method

Large Image :  98.02% Accuracy Universal RTK Antigen Test Kit Double Antibody Sandwich Method

Product Details:
Place of Origin: China
Brand Name: LABNOVATION
Certification: ISO13485,ISO9001,CE
Model Number: LX-401603
Payment & Shipping Terms:
Minimum Order Quantity: 10000 Pieces
Price: Negotiation
Packaging Details: Carton
Delivery Time: 5-7 work day
Payment Terms: T/T, D/A, D/P
Supply Ability: 500000/Day

98.02% Accuracy Universal RTK Antigen Test Kit Double Antibody Sandwich Method

Description
Total Accuracy: 98.02% Specimen: Saliva
Test Time: <15 Min Quanlity Guarantee Period: 18 Months
Storage Condition: 2℃-30℃ Group: Universal
High Light:

98.02% labnovation rtk antigen test kits

,

98.02% Accuracy rtk antigen test kits

,

ODM 98.02% Accuracy rtk antigen test kit

Rapid Tets Kit Antigen Rapid Test SARS-CoV-2 Antigen Saliva Rapid Test Kit
Intend Use
The rapid test kit is intended for the qualitative detection of SARS-CoV-2 antigen in hunman saliva samples from novel coronavirus suspected person with symptoms within 9 days from onset. Further nucleic acid detection should be carried out for suspected population whose antigen test result is positive or negative.
 
Product Details

Item Value
Brand Labnovation
Model Number LX-401601
Type 1 Test
Warranty 24 Months
Quality Certification CE, MSDS
Sample Type Saliva
Sample volume 3 Full drops
specificity 99.00%
sensitivity 94.29%
Storage Temperature 2℃-30℃

 
Product  Feature

  • Fast: Within 15 mintues you can read the test result
  • Accurate: Established with a total sample size of 505 samples, total accuracy more than 95%
  • Protable:  1 test a kit for professional testing, easy to carry
  • Simple: Simple use step, easy to do the test 

Test Principle

  • Immunochromatography assay.
  • According to the gold immunochromatographic test principle, double antibody sandwich method was used to detect SARS-CoV-2 nucleocapsid antigen in the samples..
  • Whether the sample contains antigen or not, the gold monoclonal antibody will bind to the enveloped antibody at the quality control line, form a compound and condense into a red band.

98.02% Accuracy Universal RTK Antigen Test Kit Double Antibody Sandwich Method 0

  • Main Components
  • 1 Test Cassette
  • 1 Saliva Collector With Collection Tube 
  • 1 Sample Extraction Buffer
  • 1 Package Insert

 
Use Step

  • Open the cap of the collection tube and istall saliva collector.
  • Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
  • Screw the sample extraction buffer carefully.

98.02% Accuracy Universal RTK Antigen Test Kit Double Antibody Sandwich Method 1

  • Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
  • Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
  • Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.

 98.02% Accuracy Universal RTK Antigen Test Kit Double Antibody Sandwich Method 2
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

 
 98.02% Accuracy Universal RTK Antigen Test Kit Double Antibody Sandwich Method 3
Virus Sources

Global high frequency mutation Alpha / B.1.1.7(U.K.) Beta I B.1.351(South Africa)
Gemma I P.1(Brazil) Kappa I B.1.617.1(India) Delta I B.1.617.2(India)
C.37,ect Alpha I B.1.17(U.K.) B.1.36.16.etc
A.2.5,etc A.23.1 Alpha I B.1.17(U.K.)
B.1.1.33.etc C.1.1.etc. Etc.

 