Product Details:
|
Test Time: | <15 Min | Storage Condition: | 2℃-30℃ |
---|---|---|---|
Quanlity Guarantee Period: | 24 Months | Type: | IVD Reagent |
Group: | Universal | Color: | White |
High Light: | 95% Accuracy antigen rapid testing kit,ISO13485 antigen rapid testing kit,SARS CoV 2 rapid antigen kit |
Rapid Antigen Test Kit SARS-CoV-2 Antigen Rapid Test Kit Self Testing Sinple Operation Step Antigen Rapid Test Kit
Intend Use
The SARS-CoV-2 Antigen Rapid Test Kit is intended for the qualitative detection of SARS-CoV-2 viral nucleocapsid antigens from human anterior nasal of secretion from individuals suspected of COVID-19. It is for individual self testing use, the test result can be used for early self-screening. It can be used as a basis for judging whether infection or not.
Product Details
Item | Value |
Model Number | LX-401302 |
Package | 1 Tests/Kit |
Specificity | 100.00% |
Sensitivity | 97.45% |
Total Accuracy | 99.17% |
Sample Type | Nasal Sample |
Sample volume | 3 Full drops |
Test Time | < 15 minutes |
Warranty | 24 Months |
Quality Certification | CE, MSDS,ISO9001 |
Safty Standard | ISO13485 |
Test Principle
This SARS-CoV-2 Antigen Rapid Test Kit is an immunochromatography assay which detects SARS-CoV-2 nucleocapsid antigen in the samples with the help of the double antibody sandwich method. If there is virus antigen presence in the sample, it binds with the corresponding colloidal gold antibody. In the testing process this will creates a visible red line, you can accroding the red lin to judge the sample contain antigen or not. But it need to be attention that regardless of whether the sample contains antigen or not, a reddish line forms in the Control line (C).
Product Feature
Main Components
Use Step
Notic: Let test cassette and test components stand at a room temperature (15℃ to 27℃) before performing the test.
Lay all the supplied materials on a clean, dry and flat surface.
Result Interpretation
POSITIVE: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T).
NEGATIVE: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).
INVALID: If there is no Control line (C) or only a Test line (T) in the result window, the test did not run correctly and the results are not valid.
Virus Sources
Global high frequency mutation | Alpha / B.1.1.7(U.K.) | Beta I B.1.351(South Africa) |
Gemma I P.1(Brazil) | Kappa I B.1.617.1(India) | Delta I B.1.617.2(India) |
C.37,ect | Alpha I B.1.17(U.K.) | B.1.36.16.etc |
A.2.5,etc | A.23.1 | Alpha I B.1.17(U.K.) |
B.1.1.33.etc | C.1.1.etc. |