Product Details:
|
Specimen: | Saliva | Test Speed: | Within 15 Minutes |
---|---|---|---|
Shelf Life: | 24 Months | Storage Condition: | 2℃-30℃ |
Group: | Universal | Power Source: | Instruction Manual |
High Light: | Saliva RTK Home Test Kit,CoV 2 Persnoal rtk home test kit,Single Pack self antigen test kit |
Rapid Test Kit Antigen Saliva Rapid Test CoV-2 Antigen Saliva Rapid Testing Single Pack Self Test Kit
Intend Use
This rapid test kit is intended for the qualitative detection of SARS-CoV-2 antigen in human saliva sample from novel coronavirus suspected person with symptoms within 9 days from onset. The test result can be used for early triage and rapid management of suspected populations, but it cannot be used as diagnosis basis of SARS-CoV-2 infection. For the further nucleic acid detection should be carried out for suspected population whose antigen test result is positive or negative.
Product Details
Item | Value |
Model Number | LX-401602 |
Type | 1 Test / BoX |
Warranty | 18 Months |
Power Source | Instruction Manual |
Safty Standard | ISO13485 |
After-sale Service | Online technical support |
Sample volume | 3 Full drops |
Total coincidence rate | 98.02% |
Sensitivity | 94.29% |
Specificity | 99.00% |
Product Feature
Main Components
SAMPLE COLLECTION
30 minutes before sampling, please do not eat, smoke, drinking alcohol or drinks.
SAMPLE PRESERVATION
After the samples of human saliva are collected, the saliva should be processed as soon as possible and tested within 1 hour. If it cannot be tested immediately, it can be stored at 2-8℃ for 4 hours and long-term storage is not recommended.
Use Step
Result Interpretation
POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).
NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.
INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.
Virus Sources
Global high frequency mutation | Alpha / B.1.1.7(U.K.) | Beta I B.1.351(South Africa) |
Gemma I P.1(Brazil) | Kappa I B.1.617.1(India) | Delta I B.1.617.2(India) |
C.37,ect | Alpha I B.1.17(U.K.) | B.1.36.16.etc |
A.2.5,etc | A.23.1 | Alpha I B.1.17(U.K.) |
B.1.1.33.etc | C.1.1.etc. | etc. |