HbA1C Analyzer Ues Glycosylated Hemoglobin (HbA1c) Calibrator LD-500 Fully Automatic HbA1c Analyzer Test Use

HbA1C Analyzer Ues Glycosylated Hemoglobin (HbA1c) Calibrator LD-500 Fully Automatic HbA1c Analyzer Test Use
HbA1C Analyzer Ues Glycosylated Hemoglobin (HbA1c) Calibrator LD-500 Fully Automatic HbA1c Analyzer Test Use HbA1C Analyzer Ues Glycosylated Hemoglobin (HbA1c) Calibrator LD-500 Fully Automatic HbA1c Analyzer Test Use HbA1C Analyzer Ues Glycosylated Hemoglobin (HbA1c) Calibrator LD-500 Fully Automatic HbA1c Analyzer Test Use

Large Image :  HbA1C Analyzer Ues Glycosylated Hemoglobin (HbA1c) Calibrator LD-500 Fully Automatic HbA1c Analyzer Test Use

Product Details:
Place of Origin: Shenzhen, China
Brand Name: LABNOVATION
Certification: IFCC, NGSP, CE
Payment & Shipping Terms:
Packaging Details: Carton
Delivery Time: 5-7 work day
Payment Terms: D/A, D/P, T/T

HbA1C Analyzer Ues Glycosylated Hemoglobin (HbA1c) Calibrator LD-500 Fully Automatic HbA1c Analyzer Test Use

Description
Shelf Life: 12 Months Storage Temp: 2-8℃
Application: LD-500,LD-600 Sunshine: Not Allowed
Name: Hemoglobin A1c Analyzer ODM: Yes
High Light:

OEM Glycosylated hemoglobin a1c analyzer

,

ODM Glycosylated hemoglobin a1c analyzer

,

Fully Automatic glycosylated hemoglobin analyzer

HbA1C Analyzer Ues Glycosylated Hemoglobin (HbA1c) Calibrator LD-500 Fully Automatic HbA1c Analyzer Test Use

 

Package Specification

There are two concentrations: Level 1 (low) and Level 2 (high)

Level 1 0.1mL×3 0.1mL×4 0.1mL×6 1mL×6 0.5mL×6
Level 2 0.1mL×3 0.1mL×4 0.1mL×6 1mL×6 0.5mL×6

Application

Calibrate glycosylated hemoglobin system in HbA1c analyzer

Storage And Validation

  • Stable at 2℃ – 8℃ for 12 months, direct exposure to sunshine avoided.
  • Stable for 7 days at 2℃ – 8℃ after open-vial.

Preparation For Use

  • 1. Open the vial carefully, avoiding any loss of material.
  • 2. Reconstitute by pipetting exactly 100ul of distilled water at +15°C to +25°C, into the vial.
  • 3. Close the rubber stopper and leave to stand for 10 to 15 minutes out of bright light before use.
  • 4. Swirl gently several times during the reconstitution period to ensure that the contents are completely dissolved.
  • 5. Prior to use, mix the contents by inverting the vial. Do not shake the vial as the formation of foam should be avoided. Ensure that no lyophilized material remains unreconstituted.
  • 6. Please close the rubber stopper after drawing the sample and put in the refrigerator soon to avoid containment and evaporation.

Cautions

  • Store per request and use it within the validation. The reagent out of validation should be dealt with in experimental waste way.
  • Different reagents with different lots can’t be cross used.
  • Reagent box is for IVD use only and obey the laboratory SOP.