Product Details:
Place of Origin: Shenzhen, China
Brand Name: LABNOVATION
Certification: IFCC, NGSP, CE
Model Number: LD-560
Payment & Shipping Terms:
Minimum Order Quantity: 1 Piece
Price: US$5000-12000/Piece
Packaging Details: Carton
Delivery Time: 5-7 work day
Payment Terms: D/A, D/P, T/T
Supply Ability: 100/Day

Labnovation Professional HbA1c HPLC Analyzer 100-240VAC Glycohemoglobin Analyzer

Description
Type: IVD Diagnostic Reagent Dimensions: 378mm×380mm×510mm
Test Speed: 90 Second Per Test Report Range: 3-18%
Voltage: 100-240VAC Frequency: 50/60Hz
High Light:

Labnovation HbA1c HPLC Analyzer 240VAC

,

Labnovation Professional HbA1c HPLC Analyzer

,

Labnovation 240VAC Glycohemoglobin Analyzer

HbA1c Analyzer HPLC Method Hematology Analyzer LD-560 High Accuracy Professional HbA1c Test Analyzer

Intended Use

Labnovation HbA1c Analyzer LD-560 is an fully automatic analyzer, it is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood. The LD-560 has the characteristics of small sample amount and simple operation. It is suitable for the detection of glycosylated hemoglobin in medical institutions.The analyzer consists of an auto sample injection module, a liquid chromatography separation module, a colorimetric detection and control module, a barcode scanning module, and a display printing module.

Specifications

Brand

Labnovation

Name FullY Automatic HbA1c Analyzer
Model LD-560
Method HPLC
Parameters HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional)
Test Speed 90 seconds per test
Wavelength 420nm
Sample Type Whole Blood, Pre-diluted blood
Autoloader Capacity 20 tubes
Precision CV<2%
Column Capacity 3000 tests
Working Condition Temperature: 15-30℃
Net weight 28kg
Storage environment: Temperature -20℃~55℃
Humidity 10%~93%
Equipment category Fixed
Equipment type of tested product Laboratory
Atmospheric pressure 75kPa~106kPa

 

Principle

  • Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidic cation exchanger.
  • According to the different charged properties of hemoglobin, eluents with different pH values and ionic strengths are used sequentially, and several hemoglobin components including HbA1c are separated by high performance liquid chromatography.
  • Each component is detected by a single-wavelength colorimeter, and the detected data is processed by a computer to calculate the percentage content of HbA1c in the total hemoglobin.

 

Labnovation Professional HbA1c HPLC Analyzer 100-240VAC Glycohemoglobin Analyzer 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Feature

  • Simple Maintenance
  • Full Modular Design
  • Automatic washing channel
  • Easy to change the chromatography column

Advantage

  • Fully automated operation saves time and labor
  • Automatic Primary tube sampling with cap puncture
  • Auto identificate the whole blood or lyse
  • Automatic Calibration, Can correspond to IFCC & NGSP, get reliable result.
  • Built-in quality control management simplifies quality assurance compliance
 

Labnovation Professional HbA1c HPLC Analyzer 100-240VAC Glycohemoglobin Analyzer 1

 

Performance Parameters

 

  • Repeatability: For samples with a test concentration of 4%-6%, the sample coefficient of variation (CV) of the test results is not greater than 2.0%.

  • Linear range: Within the range of 3%-18% of glycosylated hemoglobin, the linear correlation coefficient R value of the test results should not be less than 0.9900.

  • Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.

  • Basic function: Provides Chinese report and abnormal alarm.

FAQ

  • What's your delivery time?

Generally it is 5 working days if goods in stock. within 10 working days if the goods need production and also the delivery time depands on quantity

  • How to ship the product?

The shipping way normally depand on your quantity,total CBM and weight.

  • Does your product has any certificate?