Product Details:
|
Model: | LD-560 | Test Principle: | HPLC |
---|---|---|---|
CV Value: | ≤2% | Test Time: | 90s/T |
Function: | Variant Mode, Fast Mode | Test Qty: | 20 Tubes |
High Light: | ISO9001 vtm test tube Pressure Resistant,ISO9001 universal transport media tube,vtm test tube Pressure Resistant |
HPLC HbA1c Analyzer Most Effective Detection Hematology Analyzer
Specification
Method | High-Performance Liquid Chromatography (HPLC) | Sample loading capacity | 20 Tubes |
Test Modes | Fast Mode, Variant Mode | Photometer | 420nm |
Sample Type | Whole blood, Pre-diluted blood | Column Capacity | 3000T |
Test Speed | 90 Seconds/Test | Filter Capacity | 600T |
Test Range | 3% - 18% | Storage | 5000 Sample Results |
CV Precision | ≤2% | Sample Volume | 5μL |
HPLC Methodology
High-Performance Liquid Chromatography (HPLC), to separate HbA1c directly with measuring the absorbance points continually to form chromatogram. Using normal distribution curve fitting auto-iterative algorithm to get precise HbAlc testing result, excluding interference of variant and unstable hemoglobin like HbF. Standard Analysis Mode will report HbA1a, HbA1b, HbF, HbA1c, P3, HbA0 peak areas and ratio. And the result also includes IFCC, NGSP and eAG value for diverse client needs.
HPLC Technology-Gold Standard Methodology
Anchored to the Diabetes Control and Complication Trial (DCCT) reference study
NGSP and IFCC certified
Fast -To Ensure Your Workload is Processed Promptly
HbA1c results in 1.5 minutes
Fully Automated-To Minimize Operation Hassles
Automated Piercing
Fully Automated Start-up, Maintenance and Shutdown
Internal Auto Barcode Scanner for Sample identification
Precise and Reliable -To Serve You Consistently
HbA1c Inter & Intra Measuring CV's≤2%to Enable Exceptional Result Management
Superior Quality Chromatographic Resolution to Minimize Interferences
User Friendly-To Avoid Operator Error
10" Touch Screen with Vivid Color
Easy to Understand and Pellucid Software
Only one type of sample rack required for all different tubes
Reagent Alarm- Monitor Reagent Residue for Timely Reminder
Flexible -To Satisfy Diverse Laboratory's Needs
Different sample tubes can be loaded in any order in any rack
20 Sample Loader Available for Laboratory Automation
Highly customizable remarks to meet your needs
Complex System Functions -For Easy Integration
USB, USB and RS232 ports offer flexible connectivity for LIS/HIS systems
Compact Size -To Minimize Space Requirements
Small Footprint Reduces Bench Space Needed
Reagents and Consumables
600T: Eluent A/Eluent B/ Eluent C(Variant Mode) |
Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin. |
600T: Hemolysis Reagent | Used to dissolve red blood cells and release hemoglobin. |
3000T: Chromatography Column | Used for separation and elution of glycosylated hemoglobin and non glycated. |
600T: Hemoglobin Filter | Used to initially filter the sample after hemolysis. |
12Pcs: Paper Rolls | Prints a report of the test results. |