Product Details:
|
Sample Type: | Whole Blood Or Pre-diluted Blood | Parameter: | HbA1c, HbF, HbA1a, HbA1b, HbA0, HbA2(Optional) |
---|---|---|---|
Sample Volume: | Whole Blood: 5μL Pre-diluted Blood: 150μL | Display: | 10“ LCD Touch Screen |
Test Modes: | Variant Mode, Fast Mode | Sample Capacity: | 20 |
High Light: | COVID 19 Virus Sampling Tube,ISO13485 Virus Sampling Tube,Nasal Swab Collection Tube |
HbA1c Analyzer Fully Automatic Diabetes Diagnosis Prevent Diabetes Complication
Specification
Method | High-Performance Liquid Chromatography (HPLC) | Sample loading capacity | 20 Tubes |
Test Modes | Fast Mode, Variant Mode | Photometer | 420nm |
Sample Type | Whole blood, Pre-diluted blood | Column Capacity | 3000T |
Test Speed | 90 Seconds/Test | Filter Capacity | 600T |
Test Range | 3% - 18% | Storage | 5000 Sample Results |
CV Precision | ≤2% | Sample Volume | 5μL |
HPLC Methodology
High-Performance Liquid Chromatography (HPLC), to separate HbA1c directly with measuring the absorbance points continually to form chromatogram. Using normal distribution curve fitting auto-iterative algorithm to get precise HbAlc testing result, excluding interference of variant and unstable hemoglobin like HbF. Standard Analysis Mode will report HbA1a, HbA1b, HbF, HbA1c, P3, HbA0 peak areas and ratio. And the result also includes IFCC, NGSP and eAG value for diverse client needs.
HPLC Technology-Gold Standard Methodology
Anchored to the Diabetes Control and Complication Trial (DCCT) reference study
NGSP and IFCC certified
Fast -To Ensure Your Workload is Processed Promptly
HbA1c results in 1.5 minutes
Fully Automated-To Minimize Operation Hassles
Automated Piercing
Fully Automated Start-up, Maintenance and Shutdown
Internal Auto Barcode Scanner for Sample identification
Precise and Reliable -To Serve You Consistently
HbA1c Inter & Intra Measuring CV's≤2%to Enable Exceptional Result Management
Superior Quality Chromatographic Resolution to Minimize Interferences
User Friendly-To Avoid Operator Error
10" Touch Screen with Vivid Color
Easy to Understand and Pellucid Software
Only one type of sample rack required for all different tubes
Reagent Alarm- Monitor Reagent Residue for Timely Reminder
Compact Size -To Minimize Space Requirements
Small Footprint Reduces Bench Space Needed
Reagents and Consumables
600T: Eluent A/Eluent B/ Eluent C(Variant Mode) |
Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin. |
600T: Hemolysis Reagent | Used to dissolve red blood cells and release hemoglobin. |
3000T: Chromatography Column | Used for separation and elution of glycosylated hemoglobin and non glycated. |
600T: Hemoglobin Filter | Used to initially filter the sample after hemolysis. |
12Pcs: Paper Rolls | Prints a report of the test results. |