Home ProductsAntigen Rapid Test Kit

COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification

Certification
China Labnovation Technologies, Inc. certification
China Labnovation Technologies, Inc. certification
I'm Online Chat Now

COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification

COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification
COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification

Large Image :  COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification

Product Details:
Place of Origin: China
Brand Name: LABNOVATION
Certification: ISO13485,ISO9001,CE
Model Number: LX-401301
Payment & Shipping Terms:
Minimum Order Quantity: 10000 Pieces
Price: Negotiation
Packaging Details: Carton
Delivery Time: 5-7 work day
Payment Terms: T/T, D/A, D/P
Supply Ability: 500000/Day

COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification

Description
Total Accuracy: 99.60% Test Time: Within 15 Min
Quanlity Guarantee Period: 24 Months Group: Universal
Storage Condition: 2℃-30℃ Humidity: ≤60%
High Light:

COVID 19 Antigen Rapid Test Device

,

99.60% antigen rapid test device

,

Universal rapid test kit antigen

Rapid Test Kit COVID-19 Antigen Rapid Test Kit High Specification Professional Use

Antigien Rapid Test Kit

 

Intend Use
The SARS-CoV-2 antigen rapid test kit is intended for professional detection sars-cov-2 antigen in infection human nasopharyngeal or oropharyngeal swab, the test provides preliminary test results. It's an aid inthe diagnosis of the patients with suspected SARS-CoV-2 infection in conjunction with clinical presentation and results of other laboratory tests. To be attention the test result should no be used as the sole basis for diagnosis.

Product Details

Item Value
Product Name SARS-CoV-2 Antigen Rapid Test Kit
Model Number LX-401301
Type 20 Tests/Box
Sensitivity 98.04%,
Specificity 100%
Total Accuracy More tha 99%
Warranty 24 Months
Power Source Instruction Manual
Quality Certification CE
Safty Standard ISO13485,MSDS
Sample Type Nasal or Oropharyngeal Swab
Sample volume 3 Full drops
Test Speed Within 15 minutes


COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification 0
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

Product  Feature

  • High accuracy, specification and sensitivity
  • Simple operation no extra requirement
  • Detection of mutation
  • Result within 10-15 minutes
  • Safety and reliable

 

 

COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification 1
 
 
 Advantage

  • Latest design which uses faster and moe convenient operation
  • Fast recation, test accuracy up to 99%
  • Sampling swab, designed for more specimen collection and relase
  • Latest package,more convenient.


Main Components

  • Test Cassettes
  • Sample tubes 
  • Sample extraction buffers
  • Swabs
  • Instruction for use

COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification 2
Use Step

  • Add 550μL sample extraction (about 22-24 drops) into the sample tube.
  • Insert the swab into the sample tube prefilled with extraction buffer. Mix well and squeeze the swab 10-15 times by compressing the wall s of the tube against the swab.
  • Roll the swab head against the inner wall of the tubes as you remove it. Try to release as much liquid as possibe. Dispose of the used swab in accordance with your biohazard waste disposal protocol.
  • Close the cap of the sample tube.
  • Add 3 full drops of the mixed solution vertically into the sample well (S) of the test cassette.

COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification 3
 
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). 

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure.

 
COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification 4
 
Virus Sources

Global high frequency mutation Alpha / B.1.1.7(U.K.) Beta I B.1.351(South Africa)
Gemma I P.1(Brazil) Kappa I B.1.617.1(India) Delta I B.1.617.2(India)
C.37,ect Alpha I B.1.17(U.K.) B.1.36.16.etc
A.2.5,etc A.23.1 Alpha I B.1.17(U.K.)
B.1.1.33.etc C.1.1.etc.  

 
Certificate
COVID-19 Antigen Rapid Test Kit Antigen Rapid Test Device High Specification 5

Precautions

  • For IN VITRO diagnostic use only.
  • Reagents should be used as soon as possible after opened. This reagent cannot be reused for disposable.
  • The test device should remain in the sealed pouches until use. If sealing problem happens, do not test. Don’t use after the expiration date.
  • All specimens and reagents should be considered potentially hazardous and handled in the same manner as an infectious agent after use.

FAQ

  • What about the lead time for mass production?

it depends on the order quantity and the season you place the order

  • How can I do, if some urgent questions?

If you have any questions, you can call us or send us by email or whatsapp.

  • What the certification you have?

CE, ISO9001, ISO13485

  • Will you help me register the products in my country ?

Sure, we will provide all you documents and samples you need for register.

  • MOQ?

The min order quality is 10000 pcs.

  • Shipment?

Air Cargo or Ocean Cargo.

 

 

 

 

 

 

Contact Details
Labnovation Technologies, Inc.

Contact Person: Ld

Tel: +8613480985156

Send your inquiry directly to us (0 / 3000)