Product Details:
|
Test Method: | HPLC (High Performance Liquid Chromatography) | Sample Capacity: | 20 Samples |
---|---|---|---|
Testing Time: | Within 90s/T | Testing Item: | HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional) |
Certificate: | NGSP, IFCC, CE | Report Range: | 3-18% |
High Light: | IFCC Full Automated HbA1c Analyzer,Dual Mode Full Automated HbA1c Analyzer |
Labnovation Analyzer LD-560 Full Automated HbA1c Analyzer IFCC&NGSP Certificated Dual Mode Option Best Performance
Intended Use
The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin
(HbA1c) in human blood.
Specifications
Name | Fully Automated HbA1c Analyzer |
Model | LD-560 |
Method | HPLC |
Parameters | HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional) |
Test Speed | 90 seconds per test |
Wavelength | 420nm |
Sample Type | Whole Blood, Pre-diluted blood |
Autoloader Capacity | 20 tubes |
Precision | CV<2% |
Column Capacity | 3000 tests |
Working Condition | Temperature: 15-30℃ |
Accessories
No | Name | Qty | Note |
1 |
Test-tube rack | 2 PCS | / |
2 | Test-tube tray | 2 PCS | / |
3 | Waste liquid tube | 2 meters | 5/8*7/8 |
4 | Power cord | 1 PCS | GB/EU/UK /AU |
5 | Fuse wire | 2 PCS | / |
6 | Waste liquid barrel | 1 PCS | / |
7 | Operation Manual | 1 PCS | / |
8 | Certificate of conformity | 1 PCS | / |
9 | Packing list | 1 PCS | / |
10 | Warranty card | 1 PCS | / |
11 | Service card | 1 PCS | / |
Operation Preparation
Before operating this analyzer, please read the operation manual carefully to avoid malfunction or damage.
If the analyzer is used in a manner not specified by the manufacturer, the protection provided by the analyzer may be destroyed.
Before turning on the analyzer, the operator must check the following requirements to ensure that the system is ready.
(1) Check the remaining amount of reagents
Check whether the remaining amount of eluent A, eluent B, eluent C and hemolysis agent is sufficient.
(2) Check the waste liquid barrel
Check whether the waste liquid barrel has been emptied before starting the analyzer every day.
(3) Check the liquid tubes and power supply
Check whether the tubes of reagent and waste liquid are bent and whether the connections are reliable.
Check the analyzer for fluid leakage.
Check whether the power plug of the analyzer is securely inserted into the power socket.
(4) Check the printer
Check whether the paper roll is sufficient and whether it is installed in correct place.