Product Details:
|
| Principle: | HPLC (High Performance Liquid Chromatography) | Test Speed: | 90s/test |
|---|---|---|---|
| Sample Types: | Whole Blood Or Pre-diluent Sample | Test Blood Volume: | 5μL In Whole Blood Mode 150μL In Pre-diluted Mode |
| Sample Capacity: | 20 Samples | Sample Loading Method: | Continuous Automatic Sample Loading |
| Column Test Quantity: | 3000 | Reagent Pack: | 600T(Reagent)/ 3000T(Column) Separate |
| Eluent Kind: | 2 Kinds | Data Storage: | 5000 |
| Built-in Thermal Printer: | Yes | CV: | <2% |
| Test Range: | 3.0%~18.0% | Operation Screen: | 10 Inch Full Color LCD Display |
| Weiht: | 28kg | Dimensions: | 378(L) ×380(W)×510(H)mm |
| Shelf Life: | 5 Years | ||
| High Light: | Chromatographic Column HPLC HbA1c Analyzer,Fully Automatic HPLC HbA1c Analyzer,HPLC HbA1c Test Analyzer |
||
Chromatographic Column HPLC HbA1c Analyzer For HbA1c Test Fully Automatic
Specification
| Instrument | Manufacturer | Lanovation |
| Manufacture Location | China | |
| Model No | LD-560 | |
| Dection information | Principle Method | HPLC |
| Detection Mode | Fast Mode, Variant Mode | |
| Detection Method | Single wavelengh colorimetry | |
| Wavelength | 420nm | |
| Test time | 90 Seconds | |
| Test Speed Throughtput | 40 samples per hour | |
| Sample information | Sample types | Whole blood or Pre-diluent sample |
| Test Blood Volume | 5μL in whole blood mode 150μL in pre-diluted mode |
|
| Sample Capacity | 20 Tubes | |
| Sample Loading Method | Continuous automatic sample loading | |
| Mixer | No, but probe mixing samples | |
| Reagent and other consumble | Column test quantity | 3000T |
| Reagent pack |
600T(Reagent) 3000T(Column) |
|
| Eluent | 2 | |
| Operation and character information | Operation screen | 10 inch Full color LCD display |
| Data storage | 5000 | |
| Built-in Thermal Printer | Yes | |
| Performance information | CV | <2% |
| Test range | 3.0%~18.0% | |
| Package Information |
Dimensions | 378(L) ×380(W)×510(H)mm |
| Weight | 28kg |
Main Parts
The analyzer consists of an auto sample injection module, a liquid chromatography separation module, a colorimetric detection and control module, a barcode scanning module, and a display printing module.
![]()
Reagents and Consumables
| Specification | Function | |
| Eluent A |
300T*2 (1000ml*2) |
Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin. |
| Eluent B | 300T*2 (250ml*2) | |
| Eluent C(Variant Mode) | 300T*2 (650ml*2) | |
| Hemolysis Reagent |
300T*2(2300ml*2) 100ml*1 |
Used to dissolve red blood cells and release hemoglobin. |
| Hemoglobin Filter | 2um*1pc | Used to initially filter the sample after hemolysis. |
| Paper Rolls | 57*Ф30*12pcs | Prints a report of the test results. |
| Chromatography Column(Optional) | 3000T*1pc, 4.6x30mm, 5μm | Used for separation and elution of glycosylated hemoglobin and non glycated. |
Contact Person: wh@labnovation.com
Tel: +8613480985156