Product Details:
|
Principle: | HPLC (High Performance Liquid Chromatography) | Test Speed: | 90s/test |
---|---|---|---|
Sample Types: | Whole Blood Or Pre-diluent Sample | Test Blood Volume: | 5μL In Whole Blood Mode 150μL In Pre-diluted Mode |
Sample Capacity: | 20 Samples | Sample Loading Method: | Continuous Automatic Sample Loading |
Column Test Quantity: | 3000 | Reagent Pack: | 600T(Reagent)/ 3000T(Column) Separate |
Eluent Kind: | 2 Kinds | Data Storage: | 5000 |
Built-in Thermal Printer: | Yes | CV: | <2% |
Test Range: | 3.0%~18.0% | Operation Screen: | 10 Inch Full Color LCD Display |
Weiht: | 28kg | Dimensions: | 378(L) ×380(W)×510(H)mm |
Shelf Life: | 5 Years | ||
High Light: | Chromatographic Column HPLC HbA1c Analyzer,Fully Automatic HPLC HbA1c Analyzer,HPLC HbA1c Test Analyzer |
Chromatographic Column HPLC HbA1c Analyzer For HbA1c Test Fully Automatic
Specification
Instrument | Manufacturer | Lanovation |
Manufacture Location | China | |
Model No | LD-560 | |
Dection information | Principle Method | HPLC |
Detection Mode | Fast Mode, Variant Mode | |
Detection Method | Single wavelengh colorimetry | |
Wavelength | 420nm | |
Test time | 90 Seconds | |
Test Speed Throughtput | 40 samples per hour | |
Sample information | Sample types | Whole blood or Pre-diluent sample |
Test Blood Volume | 5μL in whole blood mode 150μL in pre-diluted mode |
|
Sample Capacity | 20 Tubes | |
Sample Loading Method | Continuous automatic sample loading | |
Mixer | No, but probe mixing samples | |
Reagent and other consumble | Column test quantity | 3000T |
Reagent pack |
600T(Reagent) 3000T(Column) |
|
Eluent | 2 | |
Operation and character information | Operation screen | 10 inch Full color LCD display |
Data storage | 5000 | |
Built-in Thermal Printer | Yes | |
Performance information | CV | <2% |
Test range | 3.0%~18.0% | |
Package Information |
Dimensions | 378(L) ×380(W)×510(H)mm |
Weight | 28kg |
Main Parts
The analyzer consists of an auto sample injection module, a liquid chromatography separation module, a colorimetric detection and control module, a barcode scanning module, and a display printing module.
Reagents and Consumables
Specification | Function | |
Eluent A |
300T*2 (1000ml*2) |
Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin. |
Eluent B | 300T*2 (250ml*2) | |
Eluent C(Variant Mode) | 300T*2 (650ml*2) | |
Hemolysis Reagent |
300T*2(2300ml*2) 100ml*1 |
Used to dissolve red blood cells and release hemoglobin. |
Hemoglobin Filter | 2um*1pc | Used to initially filter the sample after hemolysis. |
Paper Rolls | 57*Ф30*12pcs | Prints a report of the test results. |
Chromatography Column(Optional) | 3000T*1pc, 4.6x30mm, 5μm | Used for separation and elution of glycosylated hemoglobin and non glycated. |