Product Details:
|
Principle: | HPLC (High Performance Liquid Chromatography) | Test Speed: | 90s/test |
---|---|---|---|
Sample Types: | Whole Blood Or Pre-diluent Sample | Test Blood Volume: | 5μL In Whole Blood Mode; 150μL In Pre-diluted Mode |
Sample Loading Method: | Continuous Automatic Sample Loading | Sample Capacity: | 20 Samples |
Reagent Pack: | 600T | Column Test Quantity: | 3000T |
Eluent Kind: | Eluent A, Eluent B | Data Storage: | 5000 |
Built-in Thermal Printer: | Yes | CV: | <2% |
Test Range: | 3.0%~18.0% | Operation Screen: | 10" Full Color LCD Display |
Gross Weiht: | 28kg | Dimensions: | 378(L) ×380(W)×510(H)mm |
Shelf Life: | 5 Years | ||
High Light: | 90 Seconds HPLC HbA1c Analyzer,10" Display HPLC HbA1c Analyzer,LCD Display HPLC HbA1c Analyzer |
Analyzer For HbA1c Testing Within 90 Seconds HPLC Method Best Performance HbA1c Analyzer
Intended use
Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidic cation exchanger.
Glycosylation of hemoglobin results in a loss of surface cations that are uncharged, and non-glycosylated hemoglobin is positively charged.
According to the different charged properties of hemoglobin, several hemoglobin components including HbA1c were separated by high performance liquid chromatography using cleaning solutions of different pH values and ionic strengths.
Each component is detected by a single wavelength colorimeter, and the data is processed by a microcomputer to calculate the percentage content of HbA1c in the total hemoglobin.
*HPLC, CV<2% - Accurate and Stable
*Full Automatic smart System
*Quality & Performance - IFCC & NGSP Certificate
*User Friendly
Specification
Instrument | Manufacturer | Lanovation |
Manufacture location | Shenzhen, China | |
Model | LD-560 | |
Dection information | Principle method | HPLC |
Wavelength | 420nm | |
Test Speed | 90 Seconds/test | |
Test Speed throughtput | 40 Samples per hour | |
Sample information | Sample types | Whole blood or Pre-diluent sample |
Sample volume | 5μL in whole blood mode 150μL in pre-diluted mode |
|
Sample capacity | 20 samples | |
Sample loading method | Continuous automatic sample loading | |
Mixer | No, but probe mixing samples | |
Reagent and other consumble | Column test quantity | 3000T |
Reagent pack | 600T(Reagent)/ 3000T(Column) separate | |
Eluent | 2 | |
Operation and character information | Operation screen | 10 inch Full color LCD display |
Data storage | 5000 | |
Built-in Thermal Printer | Yes | |
Performance information | CV | <2% |
Test range | 3.0%~18.0% | |
Package Information |
Dimensions | 378(L) ×380(W)×510(H)mm |
Weight | 28kg |
Reagents and Consumables
Eluent A/Eluent B/Eluent C(Variant Mode) | Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin. |
Hemolysis Reagent | Used to dissolve red blood cells and release hemoglobin. |
Chromatography Column | Used for separation and elution of glycosylated hemoglobin and non glycated. |
Hemoglobin Filter | Used to initially filter the sample after hemolysis. |
Paper Rolls | Prints a report of the test results. |
Certificate
Contact Person: Ld