Test Time: | 90s/test | Test Principle: | HPLC (High Performance Liquid Chromatography) |
---|---|---|---|
Test Range: | 3%-18% | CV: | <2% |
Sample Capacity: | 20 Samples | Sample Types: | Whole Blood, Pre-diluent Sample |
High Light: | Diabetes Diagnosis HPLC HbA1c Analyzer,HPLC HbA1c Analyzer 90s/test,HPLC Method Automated HbA1c Analyzer |
Diabetes Diagnosis HPLC Method Automated HbA1c Analyzer
LD-560 Diabetes Diagnosis HPLC Method Automated HbA1c Analyzer is the smallest fully automatic high performance liquid chromatography analyzer. It integrates both diabetes monitoring and abnormal hemoglobin detection on a fully automated platform. Quickly detect hemoglobin such as HbA1C, HbA2, HbF, etc.Suitable for laboratories and clinical clinics within 15-30 daily samples.
Specification
Model | LD-560 |
Methodology | High-Performance Liquid Chromatography (HPLC) |
Test Modes | Fast Mode, Variant Mode |
Test Range | 3% - 18% |
Precision (CV) | <2% |
Parameter | HbA1c, HbF, HbA1a, HbA1b, HbA0, HbA2(Optional) |
First Sample Result | 4 Mins |
Test Speed | Fast Mode: 90 Seconds/Test Variant Mode: 140 Seconds/Test |
Sample Type | Whole blood, Pre-diluted blood |
Sample Volume | Whole blood: 5μL Pre-diluted blood: 150μL |
Sample loading capacity | 20 |
Photometer | 420nm |
Column Capacity | 3000T |
Filter Capacity | 600T |
Display | 10“ LCD touch screen |
Reagent Kit | Eluent A, Eluent B, Eluent C, Hemolysis, Chromatography Column |
Storage | 5000 Sample Results |
Connection interface | USB, LAN, LIS Compatible |
Printer | Thermal Printer |
System operation environment |
Temperature 15-30℃ Humidity 30%-85% |
Power | AC 100-240V 50/60HZ 300VA |
Dimensions | 378mmx380mmx510mm |
Weight | 28Kgs |
High-Performance Liquid Chromatography (HPLC), to separate HbAlc directly with measuring the absorbance points continually to form chromatogram. Using normal distribution curve fitting auto-iterative algorithm to get precise HbAlc testing result, excluding interference of variant and unstable hemoglobin like HbF. Standard Analysis Mode will report HbAla, HbAlb, HbF, HbAlc, P3, HbA0 peak areas and ratio. And the result also includes IFCC, NGSP and eAG value for diverse client needs.
* HPLC- High Correlation with import HPLC
* CV<2% - Accurate and Stable
* Full Automatated - Automated sample loading and barcode scanning
* Quality & Performance - IFCC & NGSP Certificate
Reagents and Consumables
Product | Specification | Fuction |
Eluent A | 1000ml*2 | Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin. |
Eluent B | 250ml*2 | |
Eluent C(Variant Mode) | 650ml*2 | |
Hemolysis | 2300ml*2 | Used to dissolve red blood cells and release hemoglobin. |
Chromatography Column | 1pc | Used for separation and elution of glycosylated hemoglobin and non glycated. |
Hemoglobin Filter | 1pc | Used to initially filter the sample after hemolysis. |
Paper Rolls | 12pcs | Prints a report of the test results. |