Product Details:
|
Producat Name: | Fully Automated HbA1c Analyzer Diabetes Control Analyzer For Small To Medium Clinical Laboratories | CV Value: | <2% |
---|---|---|---|
Test Time: | 90s/test | Sample Capacity: | 20 Samples |
Sample Types: | Whole Blood Or Pre-diluent Blood | Test Method: | HPLC (High Performance Liquid Chromatography) |
High Light: | Fully Automated HbA1c Analyzer 90s/test,Diabetes Control Fully Automated HbA1c Analyzer,Clinical Laboratories Diabetes Control Analyzer |
Fully Automated HbA1c Analyzer Diabetes Control Analyzer For Small To Medium Clinical Laboratories
LD-560 Fully Automated HbA1c Analyzer Diabetes Control Analyzer For Small To Medium Clinical Laboratories provides comprehensive, fully automated HbA1c and HbA2/F testing with a compact footprint within 90 seconds per test. Designed for clinics, physician offices, and clinical laboratories with small to medium sample volumes of 10-50 daily samples, fits in almost any labs and saves valuable bench space.
Specification
Name | Fully Automated HbA1c Analyzer Diabetes Control Analyzer For Small To Medium Clinical Laboratories |
Model | LD-560 |
Methodology | High-Performance Liquid Chromatography (HPLC) |
Test Modes | Fast Mode, Variant Mode |
Test Range | 3% - 18% |
Precision (CV) | <2% |
Parameter | HbA1c, HbF, HbA1a, HbA1b, HbA0, HbA2(Optional) |
First Sample Result | 4 Mins |
Test Speed | Fast Mode: 90 Seconds/Test Variant Mode: 140 Seconds/Test |
Sample Type | Whole blood, Pre-diluted blood |
Sample Volume | Whole blood: 5μL Pre-diluted blood: 150μL |
Sample loading capacity | 20 |
Photometer | 420nm |
Column Capacity | 3000T |
Filter Capacity | 600T |
Display | 10“ LCD touch screen |
Reagent Kit | Eluent A, Eluent B, Eluent C, Hemolysis, Chromatography Column |
Storage | 5000 Sample Results |
Connection interface | USB, LAN, LIS Compatible |
Printer | Thermal Printer |
System operation |
Temperature 15-30℃ Humidity 30%-85% |
Power | AC 100-240V 50/60HZ 300VA |
Dimensions | 378mmx380mmx510mm |
Weight | 28Kgs |
Performance
HPLC Technology - Gold Standard Methodology Fully Automated - To Minimize Operation Hassles
• NGSP and IFCC certified • Primary Tube Sampling with Cap Piercing
• HbAlc results in 130 seconds • Fully Automated Start-up, Maintenance
• Barcode Scanner for Sample identification
Precise and Reliable - To Serve You Consistently Compact Size - To Minimize Space Requirements
• HbAlc Inter & Intra Measuring CV's≤3%to • Small Footprint Reduces Bench Space Needed
EnableExceptional ResultManagement
• SuperiorQuality Chromatographic Resolution to
Eliminatelnterferences
High-Performance Liquid Chromatography (HPLC), to separate HbA1c directly with measuring the absorbance points continually to form chromatogram. Using normal distribution curve fitting auto-iterative algorithm to get precise HbAlc testing result, excluding interference of variant and unstable hemoglobin like HbF. Standard Analysis Mode will report HbA1a, HbA1b, HbF, HbA1c, P3, HbA0 peak areas and ratio. And the result also includes IFCC, NGSP and eAG value for diverse client needs.
Reagents and Consumables
600T: Eluent A/Eluent B/ |
Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin. |
600T: Hemolysis Reagent | Used to dissolve red blood cells and release hemoglobin. |
3000T: Chromatography Column | Used for separation and elution of glycosylated hemoglobin and non glycated. |
600T: Hemoglobin Filter | Used to initially filter the sample after hemolysis. |
12Pcs: Paper Rolls | Prints a report of the test results. |