logo
Send Message
  • English
Home ProductsPOCT HbA1c Analyzer

Fully Automatic POCT Hemoglobin A1c Analyzer LD100 Hba1c Machine For Home

Certification
China Labnovation Technologies, Inc. certification
China Labnovation Technologies, Inc. certification
I'm Online Chat Now

Fully Automatic POCT Hemoglobin A1c Analyzer LD100 Hba1c Machine For Home

Fully Automatic POCT Hemoglobin A1c Analyzer LD100 Hba1c Machine For Home
Fully Automatic POCT Hemoglobin A1c Analyzer LD100 Hba1c Machine For Home Fully Automatic POCT Hemoglobin A1c Analyzer LD100 Hba1c Machine For Home

Large Image :  Fully Automatic POCT Hemoglobin A1c Analyzer LD100 Hba1c Machine For Home

Product Details:
Place of Origin: Shenzhen, China
Brand Name: LABNOVATION
Certification: IFCC, NGSP, CE
Model Number: LD-100
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Carton
Delivery Time: 10 work day
Payment Terms: D/A, D/P, T/T
Supply Ability: 100/Day

Fully Automatic POCT Hemoglobin A1c Analyzer LD100 Hba1c Machine For Home

Description
Size: 220mm*150mm*120mm Weight: 800g
Shelf Life: 9 Months Test Speed: Within 3 Min
Method: Fluorescent Immunoturbidimetry Operating Type: 1-Step, Fully Automatic
Highlight:

LD100 POCT Hemoglobin A1c Analyzer

,

LD100 Hba1c Machines For Home

,

LD100 Hba1c Machine For Home

HbA1c Test Analyzer LD-100 POCT Testing Analyzer Fully Automatic Hematology Detection Analyzer

Intended Use

LD-100 (POCT) One-Step HbA1c Testingf Analyzer is intended for the determination of hemoglobin A1c(HbA1c) content in human whole blood. It is a semi-automatic instrument used to analyze glycated hemoglobin which can be used to detect of HbA1c in medical units at all levels in daliy life. LD-100 analyzer uses the fluorescent immunoturbidimetry, he percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Specifications

Model LD-100
Device category: Fixed
Power connection Detachable power supply cord
Measurement Time Less than 3 minutes
Sample Volume 4ul
Sample Type Whole blood
Data storage 7000
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Voltage 12VDC-3.33A
Analytical wave-length 510nm and 580nm.
Certification NGSP, IFCC

 

Fully Automatic POCT Hemoglobin A1c Analyzer LD100 Hba1c Machine For Home 0

 

PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • One-Step Testing, Automatic Detection
  • Protable and convenient
  • Fast test speed and High Accuracy
  • Battery Integrated
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • Color touch screen without extra instrument

 

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

Fully Automatic POCT Hemoglobin A1c Analyzer LD100 Hba1c Machine For Home 1

 

Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English;  Abnormal alarm function.

 

Certificated

Fully Automatic POCT Hemoglobin A1c Analyzer LD100 Hba1c Machine For Home 2

 

 

Contact Details
Labnovation Technologies, Inc.

Contact Person: Miss. Aimee li

Fax: 86-755-86368318

Send your inquiry directly to us (0 / 3000)