LD-100 Fully Automatic POCT HbA1c Analyser Hematology Testing Analyzer

Certification
China Labnovation Technologies, Inc. certification
China Labnovation Technologies, Inc. certification
I'm Online Chat Now

LD-100 Fully Automatic POCT HbA1c Analyser Hematology Testing Analyzer

LD-100 Fully Automatic POCT HbA1c Analyser Hematology Testing Analyzer
LD-100 Fully Automatic POCT HbA1c Analyser Hematology Testing Analyzer LD-100 Fully Automatic POCT HbA1c Analyser Hematology Testing Analyzer

Large Image :  LD-100 Fully Automatic POCT HbA1c Analyser Hematology Testing Analyzer

Product Details:
Place of Origin: Shenzhen, China
Brand Name: LABNOVATION
Certification: IFCC, NGSP, CE
Model Number: LD-100
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Carton
Delivery Time: 10 work day
Payment Terms: D/A, D/P, T/T
Supply Ability: 100/Day

LD-100 Fully Automatic POCT HbA1c Analyser Hematology Testing Analyzer

Description
Size: 220mm*150mm*120mm Weight: 800g
Shelf Life: 9 Months Power Connection: Detachable Power Supply Cord
Working Environment: Standard Operating Mode: Continuous
Power Supply: AC Input Power: <60VA
High Light:

Fully Automatic POCT HbA1c Analyser

,

Continuous Operating POCT HbA1c Analyser

,

POCT Automated Hematology Analyzer

HbA1c Analyzer POCT HbA1c Detection Analyzer LD-100 Fully Automatic Hematology Detection Analyzer

Intended Use

Labnovation HbA1c Analyzer LD-100 POCT Analyzer is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood which is a semi-automatic instrument used to analyze glycated hemoglobin. LD-100 is small and light, it can be used to detect of HbA1c in medical units at all levels. Fually Automatic system can help the test half work with double results.

Specifications

Model LD-100
Method Fluorescent Immunoturbidimetry
Operating Type 1-Step, fully automatic
Measurement Time Less than 3 minutes
Sample Volume 4ul
Sample Type Whole blood
Data storage 7000
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Voltage 12VDC-3.33A
Analytical wave-length 510nm and 580nm.
Certification NGSP, IFCC

 

LD-100 Fully Automatic POCT HbA1c Analyser Hematology Testing Analyzer 0

 

PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • One-Step Testing, Fully Automatic
  • Protable, easy to carry 
  • Fast test speed, WIthin 3 minutes
  • Battery Integrated
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • Color touch screen
  • External printer (Blue-tooth)
  • USB Port, LIS Support

 

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

LD-100 Fully Automatic POCT HbA1c Analyser Hematology Testing Analyzer 1

 

Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English;  Abnormal alarm function.

 

Certificated

LD-100 Fully Automatic POCT HbA1c Analyser Hematology Testing Analyzer 2

 

 

Contact Details
Labnovation Technologies, Inc.

Contact Person: Ld

Tel: +8613480985156

Send your inquiry directly to us (0 / 3000)