Laboratory Borate Affinity POCT Hba1c Analyser OEM ODM

Laboratory Borate Affinity POCT Hba1c Analyser OEM ODM
Laboratory Borate Affinity POCT Hba1c Analyser OEM ODM Laboratory Borate Affinity POCT Hba1c Analyser OEM ODM

Large Image :  Laboratory Borate Affinity POCT Hba1c Analyser OEM ODM

Product Details:
Place of Origin: Shenzhen, China
Brand Name: LABNOVATION
Certification: IFCC, NGSP, CE
Model Number: LD-100
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Carton
Delivery Time: 10 work day
Payment Terms: D/A, D/P, T/T
Supply Ability: 100/Day

Laboratory Borate Affinity POCT Hba1c Analyser OEM ODM

Description
Size: 220mm*150mm*120mm Weight: 800g
Test Speed: < 3 Min Shelf Life: 9 Months
Method: Borate Affinity Operating Type: One Step Operation
High Light:

Borate Affinity POCT Hba1c Analyser

,

Laboratory poct hba1c analyser OEM

,

ODM automated haematology analyser

HbA1c Test Analyzer Hemoglobin Detection Analysis LD-100 Poct HbA1c Fully Automatic Testing Analyzer

Intended Use

HbA1c Analyzer LD-100 is One Step HbA1c Testing Analyzer, it is intended for the content etermination of hemoglobin A1c (HbA1c) in human whole blood, It's a fully automatic HbA1c testing analyzer, one step operate process without extra instrument. LD-100 is very small and light than other analyzer in same type so it can be suitable for the detection of HbA1c in medical units at all levels.

Specifications

Name LD-100 (POCT) HbA1c Testing Analyzer
Sample Type Whole blood
Sample Volume 4ul
Testing Time Within 3 minutes
Data storage 7000
Power connection Detachable power supply cord
System Compose Sample cup mixing, Colorimetric detection And System control, Result display
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Device category: Fixed
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Voltage 12VDC-3.33A
Analytical wave-length 510nm and 580nm.
Certification NGSP, IFCC

 

Laboratory Borate Affinity POCT Hba1c Analyser OEM ODM 0

 

PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • One-Step Testing,Fully Automatic System 
  • Category of the test product: Laboratory
  • Fast test speed and High Accuracy within 3 min
  • Working environment: Standard
  • Cv<3%, Excellent Correlation With HPLC
  • Input power: <60VA
  • Color touch screen just need to clik the screen and easy to read

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

Laboratory Borate Affinity POCT Hba1c Analyser OEM ODM 1

 

Performance Parameters

  • Accuracy: Tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.