Home ProductsHematology Analyzer Reagents

Labnovation 20L 5L Medonic Hematology Reagent ISO13485

Certification
China Labnovation Technologies, Inc. certification
China Labnovation Technologies, Inc. certification
I'm Online Chat Now

Labnovation 20L 5L Medonic Hematology Reagent ISO13485

Labnovation 20L 5L Medonic Hematology Reagent ISO13485
Labnovation 20L 5L Medonic Hematology Reagent ISO13485 Labnovation 20L 5L Medonic Hematology Reagent ISO13485

Large Image :  Labnovation 20L 5L Medonic Hematology Reagent ISO13485

Product Details:
Place of Origin: China
Brand Name: LABNOVATION
Certification: ISO13485, ISO9001,CE
Payment & Shipping Terms:
Minimum Order Quantity: 500 Pieces
Price: US$8-12/Pieces
Packaging Details: Carton
Delivery Time: 10 work day
Payment Terms: D/A, D/P, T/T
Supply Ability: 500000/Day

Labnovation 20L 5L Medonic Hematology Reagent ISO13485

Description
Model Number: 99-10-020 Storage Temperature: 5-35℃
Packaging Details: 20L, 5L Expiry: 24 Months
State: Liquid Freeze: Not Allowed
High Light:

Labnovation 20L 5L Hematology Reagents

,

Labnovation 20L 5L Hematology Reagent

,

Labnovation 20L Hematology Reagent ISO13485

Hematology Analyzer Reagents Medonic Hematology Reagent For Medonic 3 Part Diff Analyzers

 
Intended Use
To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Medonic 3 part diff hematology analyzers. This product is for In Vitro Diagnostic Use only.
 
APPLICABLE INSTUMENT
For use with Medonic CA620, CA610, CA570, CA530 hematology analyzers.
 
Specification

88-10-020 DILUENT CA 20L
88-30-005 LYSER CA 5L
88-40-005 CLEANER CA 5L

 
KIT COMPOSITION

DILUENT CA NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%
LYSER CA Quaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5%
CLEANER CA Buffer<0.9% , Sufurctant<1.0%

 

Labnovation 20L 5L Medonic Hematology Reagent ISO13485 0
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Procedures 

  • Remove all the reagent aspiration tubes from the currently used reagent boxes or bottles.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Put the tubes into the LABNOVATION reagent boxes or bottles.
  • Run at least 50 backgrounds. Check for the acceptable values. At first high background counts can be seen, that should lower to normal after a few runs.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary.
Advantage
  • One source for all brands of analyzer
  • Reagents for both 3-parts and 5-parts
  • Ready-to-use final products and bulk OEM reagents
  • ISQ13485:2003 and ISO9001:2008 certified
  • CE marked, FDA cleared
  • Well-established brand used by thousands of lab in 95 countries
  • High quality, high performance and high fidelity of correlations with original brand

Storage

  • Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.
  • The open vial life of the product is 30 or 60 days (according to the table above). Unused reagents should be discarded after period of validity. Do not mix residual with a new carton.
88-10-020 DILUENT CA 24 months 60 days
88-30-005 LYSER CA 24 months 30 days
88-40-005 CLEANER CA 18 months 30 days

Labnovation 20L 5L Medonic Hematology Reagent ISO13485 1

Labnovation 20L 5L Medonic Hematology Reagent ISO13485 2
Labnovation 20L 5L Medonic Hematology Reagent ISO13485 3
PRECAUTIONS
  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.

FAQ

  • About MOQ?

We have the limit order which is 10000, we would like to cooperate with you, don't worry about MOQ, just send us of your what items you want order.

  • What is your lead time?

Stock 3-7 days in general. Or please contact us by email for specific lead time base on your order quantities.

  • Accept OEM or ODM order?

Yes, we accept both OEM and ODM for customers.

  • What are your terms of delivery?

We can accept EXW, FOB, CIF, etc. You can choose one which is the most convenient for you.

  • Manufacturer or Trade Company?

We're Manufacturer.
 

Contact Details
Labnovation Technologies, Inc.

Contact Person: Ld

Tel: +8613480985156

Send your inquiry directly to us (0 / 3000)