Home ProductsHematology Analyzer Reagents

PE-6800 PE-6300 PE-6000 Haematology Reagents For Procan 3 Part Diff Analyzers

Certification
China Labnovation Technologies, Inc. certification
China Labnovation Technologies, Inc. certification
I'm Online Chat Now

PE-6800 PE-6300 PE-6000 Haematology Reagents For Procan 3 Part Diff Analyzers

PE-6800 PE-6300 PE-6000 Haematology Reagents For Procan 3 Part Diff Analyzers
PE-6800 PE-6300 PE-6000 Haematology Reagents For Procan 3 Part Diff Analyzers PE-6800 PE-6300 PE-6000 Haematology Reagents For Procan 3 Part Diff Analyzers

Large Image :  PE-6800 PE-6300 PE-6000 Haematology Reagents For Procan 3 Part Diff Analyzers

Product Details:
Place of Origin: China
Brand Name: LABNOVATION
Certification: ISO13485, ISO9001,CE
Payment & Shipping Terms:
Minimum Order Quantity: 500 Pieces
Price: US$8-12/Pieces
Packaging Details: Carton
Delivery Time: 10 work day
Payment Terms: D/A, D/P, T/T
Supply Ability: 500000/Day

PE-6800 PE-6300 PE-6000 Haematology Reagents For Procan 3 Part Diff Analyzers

Description
Model Number: L-D01 Storage Temperature: 5-35℃
Packaging Details: 20L, 5L Expiry: 24 Months
State: Liquid Freeze: Not Allowed
High Light:

PE 6300 PE 6000 Haematology Reagents

,

PE 6300 Haematology Reagents

,

PE 6300 Haematology Reagent

Hematology Analyzer Reagents Procan Hematology Reagent For Procan 3 Part Diff Analyzers

 
Intended Use
To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Procan 3 part diff hematology analyzers. This product is for In Vitro Diagnostic Use only.
 
APPLICABLE INSTUMENT
For use with Procan PE-6800, PE-6300, PE-6000 hematology analyzers
 
Specification

L-D01 Diluent PE 20L
L-L01 LYSE PE 500 mL
L-C01 Detergent PE 5L
L-C04 10L
L-C05 20L
L-C02 Cleaner PE 500mL
L-C03 Clair PE 500mL

 
KIT COMPOSITION

Diluent PE NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%
LYSE PE NaCl, Buffer , Surfactant
Detergent PE Buffer<0.3%, Sodium Sulfate<1.5%
Cleaner PE Buffer<0.3%, Proteolytic Enzyme<0.2%
Clair PE Sodium Hypochlorite

 

PE-6800 PE-6300 PE-6000 Haematology Reagents For Procan 3 Part Diff Analyzers 0
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Procedures 

  • Remove all the reagent aspiration tubes from the currently used reagent boxes or bottles.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Put the tubes into the LABNOVATION reagent boxes or bottles.
  • Run at least 50 backgrounds. Check for the acceptable values. At first high background counts can be seen, that should lower to normal after a few runs.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary.
Advantage
  • One source for all brands of analyzer
  • Reagents for both 3-parts and 5-parts
  • Ready-to-use final products and bulk OEM reagents
  • ISQ13485:2003 and ISO9001:2008 certified
  • CE marked, FDA cleared
  • Well-established brand used by thousands of lab in 95 countries
  • High quality, high performance and high fidelity of correlations with original brand

Storage

  • Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.
  • The open vial life of the product is 30 or 60 days (according to the table above). Unused reagents should be discarded after period of validity. Do not mix residual with a new carton.
L-L01 LYSE PE 24 months 30 days
L-D01 Diluent PE 24 months 60 days
L-C01 Detergent PE  24 months 60 days
L-C04
L-C05
L-C02 Cleaner PE 18 months 30 days
L-C03 Clair PE 12 months 30 days

PE-6800 PE-6300 PE-6000 Haematology Reagents For Procan 3 Part Diff Analyzers 1

PE-6800 PE-6300 PE-6000 Haematology Reagents For Procan 3 Part Diff Analyzers 2
PE-6800 PE-6300 PE-6000 Haematology Reagents For Procan 3 Part Diff Analyzers 3
PRECAUTIONS
  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.

FAQ

  • About MOQ?

We have the limit order which is 10000, we would like to cooperate with you, don't worry about MOQ, just send us of your what items you want order.

  • What is your lead time?

Stock 3-7 days in general. Or please contact us by email for specific lead time base on your order quantities.

  • Accept OEM or ODM order?

Yes, we accept both OEM and ODM for customers.

  • What are your terms of delivery?

We can accept EXW, FOB, CIF, etc. You can choose one which is the most convenient for you.

  • Manufacturer or Trade Company?

We're Manufacturer.
 

Contact Details
Labnovation Technologies, Inc.

Contact Person: Ld

Tel: +8613480985156

Send your inquiry directly to us (0 / 3000)