Home ProductsPOCT HbA1c Analyzer

LD-100 POCT HbA1c Analyser One Step Automatic Hematology Detection Analyzer

Certification
China Labnovation Technologies, Inc. certification
China Labnovation Technologies, Inc. certification
I'm Online Chat Now

LD-100 POCT HbA1c Analyser One Step Automatic Hematology Detection Analyzer

LD-100 POCT HbA1c Analyser One Step Automatic Hematology Detection Analyzer
LD-100 POCT HbA1c Analyser One Step Automatic Hematology Detection Analyzer LD-100 POCT HbA1c Analyser One Step Automatic Hematology Detection Analyzer

Large Image :  LD-100 POCT HbA1c Analyser One Step Automatic Hematology Detection Analyzer

Product Details:
Place of Origin: Shenzhen, China
Brand Name: LABNOVATION
Certification: IFCC, NGSP, CE
Model Number: LD-100
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Carton
Delivery Time: 10 work day
Payment Terms: D/A, D/P, T/T
Supply Ability: 100/Day

LD-100 POCT HbA1c Analyser One Step Automatic Hematology Detection Analyzer

Description
Size: 220mm*150mm*120mm Working Environment: Standard
Shelf Life: 9 Months Operating Mode: Continuous
Net Weight: ≤5kg Data Storage: 7000
High Light:

One Step POCT HbA1c Analyser

,

Automatic POCT HbA1c Analyser

,

Automatic Hematology Detection Analyzer

HbA1c Analyzer POCT HbA1c Analyzer LD-100 One Step Automatic Hematology Detection Analyzer

Intended Use

  • It is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood. 
  • HbA1c Analyzer is a semi-automatic instrument used to analyze glycated hemoglobin.
  • It has the characteristics of small sample consumption and easy operation.
  • It is suitable for the detection of HbA1c in medical units at all levels.HbA1c Analyzer is composed of the systems of sample cup mixing, colorimetric detection and system control, result display.

Specifications

Model LD-100
Method Boronate Affinity
Operating Type 1-Step, fully automatic
Measurement Time Less than 3 minutes
Sample Type Whole blood
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Shelf-Life of Test Kit 9 months
Voltage 12VDC-3.33A
Sample Volume 4ul
Power connection Detachable power supply cord
Device category Fixed
Operating mode Continuous

 

LD-100 POCT HbA1c Analyser One Step Automatic Hematology Detection Analyzer 0

 

PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • One-step Operation
  • Boronate Affinity
  • Battery Integrated
  • Portable, Compact
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • Color touch screen
  • External printer (Blue-tooth)
  • USB Port
  • LIS Support

 

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge

LD-100 POCT HbA1c Analyser One Step Automatic Hematology Detection Analyzer 1

 

Performance Parameters

  • Accuracy:The accuracy is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and the relative deviation of the test results is not more than ±3%.
  • Permission: The authority is the first-level authority, and the login authority is the first-level authority

 

Certificated

LD-100 POCT HbA1c Analyser One Step Automatic Hematology Detection Analyzer 2

 

 

Contact Details
Labnovation Technologies, Inc.

Contact Person: Ld

Tel: +8613480985156

Send your inquiry directly to us (0 / 3000)