Home ProductsHematology Analyzer Reagents

Hematology Analyzer Reagents excellent Performance Hematology Reagent For Nihon Khoden 3 Part Diff Analyzers

Certification
China Labnovation Technologies, Inc. certification
China Labnovation Technologies, Inc. certification
I'm Online Chat Now

Hematology Analyzer Reagents excellent Performance Hematology Reagent For Nihon Khoden 3 Part Diff Analyzers

Hematology Analyzer Reagents excellent Performance Hematology Reagent For Nihon Khoden 3 Part Diff Analyzers
Hematology Analyzer Reagents excellent Performance Hematology Reagent For Nihon Khoden 3 Part Diff Analyzers Hematology Analyzer Reagents excellent Performance Hematology Reagent For Nihon Khoden 3 Part Diff Analyzers

Large Image :  Hematology Analyzer Reagents excellent Performance Hematology Reagent For Nihon Khoden 3 Part Diff Analyzers

Product Details:
Place of Origin: China
Brand Name: LABNOVATION
Certification: ISO13485, ISO9001,CE
Payment & Shipping Terms:
Minimum Order Quantity: 500 Pieces
Price: US$8-12/Pieces
Packaging Details: Carton
Delivery Time: 10 work day
Payment Terms: D/A, D/P, T/T
Supply Ability: 500000/Day

Hematology Analyzer Reagents excellent Performance Hematology Reagent For Nihon Khoden 3 Part Diff Analyzers

Description
Model Number: 41-10-020 Packaging Details: 20L, 500ML,5L
Expiry: 24 Months Suitable For: Coagulation Analyzer
State: Liquid Instrument Classiific: Class 1

Hematology Analyzer Reagents Excellent Performance Hematology Reagent For Nihon Khoden 3 Part Diff Analyzers

 

Intended Use

To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Nihon Khoden 3 part diff hematology analyzers. This product is for In Vitro Diagnostic Use only.

Applicable Instument

For use with Nihon Kohden MEK-6318,MEK-6400,MEK-6700, MEK-6410,MEK-6420 hematology analyzers.

Procedures

  • Remove all the reagent aspiration tubes from the currently used reagent boxes.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water. Put the tubes into Labnovation reagents boxes or bottles.
  • Run at least 50 backgrounds. Check for the acceptable background values. At first background counts can be seen, that should lower to normal after a few runs.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary.
Precaution
  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.
Hematology Analyzer Reagents excellent Performance Hematology Reagent For Nihon Khoden 3 Part Diff Analyzers 0
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Specification

41-10-020 Diluent NK 20L
41-30-A05 Lyse NK  500ML X3
41-40-005R Rinse NK 5 L
L-0401005 Cleaner-C 500ML 

 

KIT COMPOSITION

DILUENT NK NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%
CLEANER-C Sodium Hypochlorite 5%
LYSE NK Quaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5%
RINSE NK Buffer<0.9%, Sufurctant<1.0%
 
Hematology Analyzer Reagents excellent Performance Hematology Reagent For Nihon Khoden 3 Part Diff Analyzers 1
Hematology Analyzer Reagents excellent Performance Hematology Reagent For Nihon Khoden 3 Part Diff Analyzers 2

 Storage

Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.

The open vial life of the product is 30/60 days. Unused reagents should be discarded after 30/60 days. Do not mix residual with a new carton.

Hematology Analyzer Reagents excellent Performance Hematology Reagent For Nihon Khoden 3 Part Diff Analyzers 3
Advantage
  • One source for all brands of analyzer 
  • Reagents for both 3-parts and 5-parts
  • Ready-to-use final products and bulk OEM reagents
  • ISQ13485:2003 and ISO9001:2008 certified
  • CE marked, FDA cleared
  • Well-established brand used by thousands of lab in 95 countries
  • High quality, high performance and high fidelity of correlations with original brand
 
 

Contact Details
Labnovation Technologies, Inc.

Contact Person: Ld

Tel: +8613480985156

Send your inquiry directly to us (0 / 3000)