Home ProductsHematology Analyzer Reagents

Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents

Certification
China Labnovation Technologies, Inc. certification
China Labnovation Technologies, Inc. certification
I'm Online Chat Now

Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents

Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents
Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents

Large Image :  Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents

Product Details:
Place of Origin: China
Brand Name: LABNOVATION
Certification: ISO13485, ISO9001,CE
Payment & Shipping Terms:
Minimum Order Quantity: 500 Pieces
Price: US$8-12/Pieces
Packaging Details: Carton
Delivery Time: 10 work day
Payment Terms: D/A, D/P, T/T
Supply Ability: 500000/Day

Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents

Description
Model Number: 20-10-020 Packaging Details: 20L, 500ML,50ML
Expiry: 24 Months Suitable For: Coagulation Analyzer
State: Liquid Instrument Classiific: Class 1

Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents

 

Intended Use

To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on Sysmex XT-2000i, XT-1800i hematology analyzers. This product is for In Vitro Diagnostic Use only.

Precautions
  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.
Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents 0
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Specification

20-10-020 DILUENT-ST 20 L
23-30-FFD 4DL-LYSER 5 L
23-30-FFS-8-01 4DS-LYSER 1 L
23-30-SLS-A05 SLS-LYSER 500ML×3
23-30-FBA-A5 FB-LYSER 5 L
21-CL-50 CELL-CLEANER 50 ML

 

KIT COMPOSITION

DILUENT-ST NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%
4DL-LYSER Non-ionic Surfactant<0.2%
4DS-LYSER

Ethylene glycol>90%, Polymethine dye<0.006%

SLS-LYSER Sodium Lauryl Sulfate<0.2%
FB-LYSER Non-ionic Surfactant<0.5%
CELL-CLEANER Sodium Hypochlorite 5%
 
Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents 1
Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents 2

 Procedures

  • Remove the diluents tubing from the currently used Cellpack.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Loosen and remove the cap on the cubitainers or bottles or sachet, attach the dispenser assembly to the cubintainer or bottle or sachet, then tighten the caps.
  • Connect the other reagents to the analyzer in the same way.
  • Prime the reagents though the instrument completely according to the operator’s manual.
  • Recalibrate the unit if necessary.
Hematology Reagent For Sysmex Xt-2000i, Xt-1800i Analyzers Best Performance Hematology Analyzer Reagents 3

Storage

  • Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.
  • The open vial life of the product is 30/60 days. Unused reagents should be discarded after 30/60 days. Do not mix residual with a new carton. 
Advantage
  • One source for all brands of analyzer 
  • Reagents for both 3-parts and 5-parts
  • Ready-to-use final products and bulk OEM reagents
  • ISQ13485:2003 and ISO9001:2008 certified
  • CE marked, FDA cleared
  • Well-established brand used by thousands of lab in 95 countries
  • High quality, high performance and high fidelity of correlations with original brand
 
 

Contact Details
Labnovation Technologies, Inc.

Contact Person: Ld

Tel: +8613480985156

Send your inquiry directly to us (0 / 3000)