Home ProductsPOCT HbA1c Analyzer

Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample

Certification
China Labnovation Technologies, Inc. certification
China Labnovation Technologies, Inc. certification
I'm Online Chat Now

Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample

Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample
Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample

Large Image :  Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample

Product Details:
Place of Origin: Shenzhen, China
Brand Name: LABNOVATION
Certification: IFCC, NGSP, CE
Model Number: LD-100
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Carton
Delivery Time: 15-20 working days
Payment Terms: D/A, D/P, T/T
Supply Ability: 100/Day

Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample

Description
Sample Types: Whole Blood Test Blood Volume: 4μL
Test Speed Throughtput: 20 Samples Per Hour Test Time: <3 Minutes
Principle: Borate Affinity Fluorescent Immunoturbidimetry Data Storage: 7000 Tests
High Light:

Battery Integrated POCT HbA1c Analyzer

,

Whole Blood POCT HbA1c Analyzer

LD-100 Analyzer POCT Best Performance IFCC&NGSP Certificated Battery Integrated One Step Use HbA1c Analyzer

 

Intended Use

Labnovation HbA1c Analyzer LD-100 POCT Analyzer is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood which is a semi-automatic instrument used to analyze glycated hemoglobin. LD-100 is small and light, it can be used to detect of HbA1c in medical units at all levels. Fually Automatic system can help the test half work with double results.

 

 

Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample 0

 

Specifications

Model LD-100
Sample Type Whole blood
Sample Volume 4ul
Test Time Less than 3 minutes
Data storage 7000
Method Fluorescent Immunoturbidimetry
Operating Type 1-Step Operation, Fully automatic system
Measurement Range HbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating Condition Temperature:15~35℃
Humidity:15~80%R.H
Storage Condition Analyzer:10-60℃; Test kit: 2~8℃
Voltage 12VDC-3.33A
Analytical wave-length 510nm and 580nm.
Certification NGSP, IFCC
 
 
Working Principles
HbA1c Analyzer uses the (borate affinity) fluorescent immunoturbidimetry. Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently. The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells. The total concentration of hemoglobin depends on the initial reduced fluorescence signal. Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients. The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

 

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

Performance

  • Result reporting unit

Glycated hemoglobin (HbA1c) is reported by default in IFCC units (mmol/mol) and NGSP units (%).

  • Accuracy

The accuracy is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.

  • Precision

Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.

  • Linearity

In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.

  • Stability

Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and POCT HbA1c Analyzer V1.0 2 the relative deviation of the test results is not more than ±3%.

 

 

Certificate

Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample 1Battery Integrated POCT HbA1c Analyzer One Step 4uL Whole Blood Sample 2

 

Attention

The HbA1c Analyzer meets the emission and immunity requirements specified in the relevant Section of GB/T 18268.26, as shown in the table below.

  • Users have the responsibility to ensure the electromagnetic compatibility environment of the equipment, so that the equipment can work properly. 
  • It is recommended that the electromagnetic environment be evaluated before the equipment is used.

 

 

Contact Details
Labnovation Technologies, Inc.

Contact Person: Ld

Tel: +8613480985156

Send your inquiry directly to us (0 / 3000)