Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test

Certification
China Labnovation Technologies, Inc. certification
China Labnovation Technologies, Inc. certification
I'm Online Chat Now

Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test

Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test
Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test

Large Image :  Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test

Product Details:
Place of Origin: Shenzhen, China
Brand Name: LABNOVATION
Certification: IFCC, NGSP, CE
Model Number: LD-100
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Carton
Delivery Time: 15-20 working days
Payment Terms: D/A, D/P, T/T
Supply Ability: 100/Day

Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test

Description
Name: Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test Test Speed: ≤2 Minutes
Sample Type: Whole Blood Sample Volume: 4μL
Test Range: 4%-15% CV: ≤3%
High Light:

Individual POCT HbA1c Analyzer

,

Cartridge POCT HbA1c Analyzer

Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test

 

The Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin TestI is a automated desktop point-of-care analyzer for measuring glycated hemoglobin (HbA1c) to diabetes diagosis.

 

The Test Cartridge is individually packaged containing the reagents necessary for the determination of hemoglobin A1c one test.

 


Specification

 

Model LD-100
Method Boronate Affinity
Measurement Time ≤2 minutes
Sample Type Whole blood
Measurement Range 4.0-15%
Sample Volume 4μL
Shelf life of test kit 9 months
Weight ≤800g
Dimensions 192(L)*128(W)*108(H)mm
 

 


Principle

 

The analyzer works based on the principle of boric acid affinity fluorescence quenching. The content of HbA1c is quantitatively detected by detecting the amount of fluorescent substance changing with the binding and quenching of HbA1c and fluorescent substance.

 

 

 

 

Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test 0

The Application of Boronate affinity in Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test.

 

After the magnetic beads are pushed into the kit, the borate in the reagent binds to the fluorophore in the magnetic beads, resulting in a large amount of excited fluorescence

After the magnetic beads are pushed into the kit, the borate binds to the fluorophore, producing a large amount of excited fluorescence.

After the sample is added to the reagent, the borate-fluorophore competes with hemoglobin for binding, resulting in a decrease in fluorescence. Because the binding force of unglycated hemoglobin is much greater than that of glycated hemoglobin, the unglycated hemoglobin first binds to the borate-fluorophore, resulting in a sharp drop in fluorescence. The content of unglycated components can be detected during this process.

Next, the glycosylated hemoglobin is bound to a borate-fluorophore. This binding process is slow and therefore the fluorescence quenching process is slow and curvilinear. The fluorescence quenching process in the detection cycle of the instrument can reflect the content of glycosylated hemoglobin.

 

 

 


Feature

 

Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).


 

 


Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-15% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English;  Abnormal alarm function.

 