Glycosylated Hemoglobin Diabetes Measuring Device 2 Minutes POCT HbA1c Analyzer

Certification
China Labnovation Technologies, Inc. certification
China Labnovation Technologies, Inc. certification
I'm Online Chat Now

Glycosylated Hemoglobin Diabetes Measuring Device 2 Minutes POCT HbA1c Analyzer

Glycosylated Hemoglobin Diabetes Measuring Device 2 Minutes POCT HbA1c Analyzer
Glycosylated Hemoglobin Diabetes Measuring Device 2 Minutes POCT HbA1c Analyzer

Large Image :  Glycosylated Hemoglobin Diabetes Measuring Device 2 Minutes POCT HbA1c Analyzer

Product Details:
Place of Origin: Shenzhen, China
Brand Name: LABNOVATION
Certification: IFCC, NGSP, CE
Model Number: LD-100
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: Carton
Delivery Time: 15-20 working days
Payment Terms: D/A, D/P, T/T
Supply Ability: 100/Day

Glycosylated Hemoglobin Diabetes Measuring Device 2 Minutes POCT HbA1c Analyzer

Description
Product Name: Glycosylated Hemoglobin Measuring Device POCT HbA1c Analyzer Sample Type: Whole Blood
Test Time: ≤2 Minutes Sample Volume: 4μL
Test Range: 4%-15% CV Precision: ≤3%
High Light:

HbA1c Diabetes Measuring Device

,

Glycosylated Hemoglobin Diabetes Measuring Device

,

2 Minutes POCT HbA1c Analyzer

Glycosylated Hemoglobin Measuring Device POCT HbA1c Analyzer

 

Glycosylated Hemoglobin Measuring Device POCT HbA1c Analyzer is intended for measuring glycoslated hemoglobin (HbA1c) in human blood.

It is applicable to the quantitative detection of HbA1c in venous blood in EDTA test tube.

According to the most recent IDF data, 537 million people—approximately 10% of all people aged 20-79 in the world—were living with diabetes as of 2021. 

With the development of modern medicine, people pay more and more attention to their own health and the diagnosis and control of diabetes has become a hot topic. As we know, diabetes is a group of metabolic diseases characterized by hyperglycemia. Every Patient with diabetes is adviced to have their HbA1c tested for 2-4 times annually.

The analyzer works based on the principle of boronate affinity fluorescence quenching. The content of HbA1c is quantitatively detected by detecting the amount of fluorescent substance changing with the binding and quenching of HbA1c and fluorescent substance.

 


Specification

 

Product Name Glycosylated Hemoglobin Measuring Device POCT HbA1c Analyzer
Model LD-100
Method Boronate Affinity
Measurement Time ≤2 minutes
Sample Type Whole blood
Measurement Range 4.0-15%
Sample Volume 4μL
Analysis Wavelength 510nm & 580nm
Shelf life of test kit 9 months
Data Storage 7,000
Storage conditions 20 ℃ ~ 55 ℃
Weight ≤800g
Dimensions 192(L)*128(W)*108(H)mm

 

 

 

 

Glycosylated Hemoglobin Diabetes Measuring Device 2 Minutes POCT HbA1c Analyzer 0

 


Feature

 

Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).

 

 


Performance Indicators

  • Accuracy: The accuracy shall be measured with reference materials as samples, and the relative deviation of the results measured by the analyzer shall be less than ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-15% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English;  Abnormal alarm function.

 